What was found
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 1 INCH CRACKED FRAME STA 1064 STR 16R. CUT OUT DAMAGE, FABRICATED DOUBLER AND INSTALLED, REPAIRED PER SRM 51-40-3 FIG 1. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 1 INCH CRACKED FRAME STA 1064 STR 16R. CUT OUT DAMAGE, FABRICATED DOUBLER AND INSTALLED, REPAIRED PER SRM 51-40-3 FIG 1. (X)