INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH CORROSION STA 312 RBL 10 FLOOR BEAM. INSTALLED T-CAP STA RBL 20 TO LBL 19. REPAIRED PER TYPICAL REPAIR MANUAL 53-10-03. CORROSION TASK NR: C53-107-02. CORROSION LEVEL: 2. (X)