What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION 1.25 INCH STATION 970 STRINGER 27L. REPLACED STRINGER SECTION, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION 1.25 INCH STATION 970 STRINGER 27L. REPLACED STRINGER SECTION, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 1. (M)