What was found
PIT - DURING Q1 CHECK, FOUND DEEP CHAFE IN BELT FRAME AT STA 332 ABOVE LONGERON 30. INSTALLED SPLICE BETWEEN LONGERON 28L AND LONGERON 26R PER SRM 53-03 FIG 2A. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q1 CHECK, FOUND DEEP CHAFE IN BELT FRAME AT STA 332 ABOVE LONGERON 30. INSTALLED SPLICE BETWEEN LONGERON 28L AND LONGERON 26R PER SRM 53-03 FIG 2A. (X)