What was found
DURING C-1 CHECK VISUAL INSPECTION, FOUND 1 BY .750 CORROSION TOP OF FLOORBEAM AT BS 312 RBL 8 FORWARD SIDE OF FLANGE. INSTALLED STRAPS AS PER TR 53-10-01A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-1 CHECK VISUAL INSPECTION, FOUND 1 BY .750 CORROSION TOP OF FLOORBEAM AT BS 312 RBL 8 FORWARD SIDE OF FLANGE. INSTALLED STRAPS AS PER TR 53-10-01A. (M)