What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CORRODED AREA BS 919, STRINGER 25L. SPLICED STRINGER, REPAIRED PER SRM 53-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CORRODED AREA BS 919, STRINGER 25L. SPLICED STRINGER, REPAIRED PER SRM 53-10-3. (M)