What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1.5 INCH CRACK BS 639 STRINGER 16L FRAME. INSTALLED REPAIR PER DRAWING 65C31658. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1.5 INCH CRACK BS 639 STRINGER 16L FRAME. INSTALLED REPAIR PER DRAWING 65C31658. (M)