What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION AT OUTER AREA OF STRINGER WHERE MATES W/SKIN 15 INCHES LONG BY 1 INCH WIDE, SOME AREAS COMPLETELY THROUGH STRINGER, STATION 360-375 STRINGER 25L. INSTALLED NEW SEGMENT OF STRINGER, REPAIRED PER SRM 53-10-3 FIG 1. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)