What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA BS 907, STRINGER 24L. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCH CORRODED AREA BS 907, STRINGER 24L. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)