What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORRODED AREA AFT CARGO BS 907 STRINGER 26R. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3 FIG 1 SRM 53-10-4 FIG 10. CORROSION TASK NR C53-208-01, CORROSION LEVEL 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORRODED AREA AFT CARGO BS 907 STRINGER 26R. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3 FIG 1 SRM 53-10-4 FIG 10. CORROSION TASK NR C53-208-01, CORROSION LEVEL 1. (M)