What was found
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND DENTS 2.5 INCH BY 3 INCH AND 1.5 INCH BY 1.5 INCH STATION 807 BETWEEN STRINGER 19L AND 20L SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3 FIG 6. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND DENTS 2.5 INCH BY 3 INCH AND 1.5 INCH BY 1.5 INCH STATION 807 BETWEEN STRINGER 19L AND 20L SKIN. INSTALLED DOUBLER, REPAIRED PER SRM 53-30-3 FIG 6. (M)