What was found
PIT - FOUND 1 INCH CRACK IN 4 LONGERON, STATION 617, LONGERON 5RT AND 5LT STATION 639 LONGERON 8LT STATION 737 LONGERON 3RT. DETECTED BY EDDY CURRENT. INSTALLED SPLICE REPAIRS PER TYPICAL REPAIR 53-10-17. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND 1 INCH CRACK IN 4 LONGERON, STATION 617, LONGERON 5RT AND 5LT STATION 639 LONGERON 8LT STATION 737 LONGERON 3RT. DETECTED BY EDDY CURRENT. INSTALLED SPLICE REPAIRS PER TYPICAL REPAIR 53-10-17. (M)