What was found
CLT - DURING CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK AT STATION 807 AT STRINGER 20L ON SKIN. INSTALLED DOUBLER WITH BLIND FASTENERS PER REPAIR DOCUMENT SRM 53-30-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING CHECK VISUAL INSPECTION, FOUND A 1.5 INCH CRACK AT STATION 807 AT STRINGER 20L ON SKIN. INSTALLED DOUBLER WITH BLIND FASTENERS PER REPAIR DOCUMENT SRM 53-30-3 FIG 1. (M)