What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION FOUND A 42 INCH BY 1.5 INCH CORROSION ON FLOORBEAM AT STATION 967 LBL 4 AND LBL 46. CORROSION TASK NR C53-107-02. SPLICED IN NEW T-CAP FROM LBL 4 TO LBL 46 STATION 967 AS PER SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-6 CHECK VISUAL INSPECTION FOUND A 42 INCH BY 1.5 INCH CORROSION ON FLOORBEAM AT STATION 967 LBL 4 AND LBL 46. CORROSION TASK NR C53-107-02. SPLICED IN NEW T-CAP FROM LBL 4 TO LBL 46 STATION 967 AS PER SRM 53-00-51. (M)