What was found
CLT - DURING Q-4 VISUAL INSPECTION, FOUND A .500 INCH AREA OF CORROSION STA 967 FLOOR BEAM AT LBBL 18.0. CORROSION TASK NR C53-107-02. REMOVED CORROSION, FABRICATED FILLER AND DOUBLERS PER REPAIR DOCUMENT SRM 53-00-51. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 VISUAL INSPECTION, FOUND A .500 INCH AREA OF CORROSION STA 967 FLOOR BEAM AT LBBL 18.0. CORROSION TASK NR C53-107-02. REMOVED CORROSION, FABRICATED FILLER AND DOUBLERS PER REPAIR DOCUMENT SRM 53-00-51. (X)