What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH AREA CRACKED AT BS 296 STRINGER 17R DOOR FRAME. CUT OUT DAMAGED SECTION, INSTALLED DOUBLER, REPAIRED PER SRM 51-70-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH AREA CRACKED AT BS 296 STRINGER 17R DOOR FRAME. CUT OUT DAMAGED SECTION, INSTALLED DOUBLER, REPAIRED PER SRM 51-70-11. (M)