What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION AROUND NUTPLATE HOLE ON FLOORBOARD BEAM BS 328 LBL 54. INSTALLED NUTPLATE REPAIR, REPAIRED PER TR 53-10-13. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION AROUND NUTPLATE HOLE ON FLOORBOARD BEAM BS 328 LBL 54. INSTALLED NUTPLATE REPAIR, REPAIRED PER TR 53-10-13. (M)