What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND FLANGE WORN AT SCREW HOLES FORWARD OF BS 727 RIGHT SIDE KEEL BEAM LOWER CHORD. BLENDED DAMAGE AREAS AND INSTALLED FABRICATED REPAIR, REPAIRED PER EA 4329. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND FLANGE WORN AT SCREW HOLES FORWARD OF BS 727 RIGHT SIDE KEEL BEAM LOWER CHORD. BLENDED DAMAGE AREAS AND INSTALLED FABRICATED REPAIR, REPAIRED PER EA 4329. (M)