What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM .5 INCH BY .5 INCH AT CLIPNUTS STATION 377 FROM BL 0 TO LBBL 60. INSTALLED NEW FLOORBEAM AND REPAIRED DOUBLERS PER SRM 51-20-01, SRM 20-41-02 AND SRM 53-00-51 FIGURE 203. (M)