As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION ON TOP OF FLOORBEAM AT THE SCREW HOLES AT STATION 967 FLOORBEAM. CORROSION TASK NR C-53-107-02. BURNISHED AND TREATED AREA OF MINOR CORROSION. REPLACED T-CAP WHERE NECESSARY PER REPAIR DOCUMENT AND SRM 53-00-51 AND TYPICAL REPAIR NR 53-10-05. (M)