What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION AT STRINGER 21L, STATION 887 STRINGER. CORROSION TASK NR C 53-202-01. INSTALLED STRINGER SPLICE PER REPAIR DOCUMENT SRM 53-00-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION AT STRINGER 21L, STATION 887 STRINGER. CORROSION TASK NR C 53-202-01. INSTALLED STRINGER SPLICE PER REPAIR DOCUMENT SRM 53-00-03. (M)