What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION FOUND APPROX 2 INCH BY 2 INCH AREA CORRODED STRINGER 25L AT STATION 968. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION FOUND APPROX 2 INCH BY 2 INCH AREA CORRODED STRINGER 25L AT STATION 968. INSTALLED STRINGER SPLICE, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)