What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH CORRODED AREA BS 990 WL 208 STRINGER 17R FRAME. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-107-07, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH CORRODED AREA BS 990 WL 208 STRINGER 17R FRAME. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-107-07, CORROSION LEVEL 2. (M)