INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 CRACKS, .5 INCH AND 1.5 INCHES LONG AT BS 520 RBL 45 FLOORBEAM. INSTALLED KIT, REPAIRED PER EA 43461. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 CRACKS, .5 INCH AND 1.5 INCHES LONG AT BS 520 RBL 45 FLOORBEAM. INSTALLED KIT, REPAIRED PER EA 43461. (M)