What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK FLOORBEAM BS 520, RBL 24. INSTALLED DOUBLER AND MOD REPAIRED PER EA 43461. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 INCH CRACK FLOORBEAM BS 520, RBL 24. INSTALLED DOUBLER AND MOD REPAIRED PER EA 43461. (M)