What was found
PIT - DURING Q-6 CHECK, FOUND 1 INCH BY 1 INCH AND 1.5 INCH BY 2 INCH AREAS OF CORROSION UNDE RT WING TO FUSELAGE FILLET PANEL ON SKIN, STATION 769. BLENDED AREAS AND INSTALLED DOUBLERS PER SRM 53-04 FIG 53. CORROSION LEVEL 1, CORROSIN TASK NR C22-57301. (M)