What was found
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 46 INCH BY 1 INCH CORROSION AREA ON FLOORBEAM STATION 345 BL 0 TO RBL 46 UPPER FLANGE. REPAIR T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 46 INCH BY 1 INCH CORROSION AREA ON FLOORBEAM STATION 345 BL 0 TO RBL 46 UPPER FLANGE. REPAIR T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)