What was found
CLT - DURING A VISUAL CHECK INSPECTION, FOUND A 61.24 INCH OF CORROSION ON THE FLOORBEAM UPPER CHORD AT STATION 365 FROM BL 0 TO RBL 45.5. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING A VISUAL CHECK INSPECTION, FOUND A 61.24 INCH OF CORROSION ON THE FLOORBEAM UPPER CHORD AT STATION 365 FROM BL 0 TO RBL 45.5. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)