CLT - DURING A CHECK VISUAL INSPECTION, FOUND A 217 INCH CORROSION ON FLOORBEAM UPPER CHORD FROM LBL 62 TO RBL 62 STATION 345. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)