What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK LOWER AFT CORNER FORWARD SERVICE DOOR CUTOUT STATION 328 STRINGER 17 SKIN AND BARE STRAP. INSTALLED DOUBLERS PER SRM 53-30-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK LOWER AFT CORNER FORWARD SERVICE DOOR CUTOUT STATION 328 STRINGER 17 SKIN AND BARE STRAP. INSTALLED DOUBLERS PER SRM 53-30-3. (M)