What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .75 INCH CRACK STATION 178 BULKHEAD LBL 5, WL 199. INSTALLED DOUBLER REPAIRED PER SRM 53-10-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .75 INCH CRACK STATION 178 BULKHEAD LBL 5, WL 199. INSTALLED DOUBLER REPAIRED PER SRM 53-10-11. (M)