What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACK .5 INCH AT STATION 328 STRINGER 20R FRAME. INSTALLED REPAIR DOUBLER, REPAIRED PER SRM 51-40-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CRACK .5 INCH AT STATION 328 STRINGER 20R FRAME. INSTALLED REPAIR DOUBLER, REPAIRED PER SRM 51-40-3. (M)