What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 12 INCH SECTION OF CORROSION STRINGER 27L, BS 967 AND BS 987 STRINGERS. CUTOUT STRINGER, FABRICATED REPAIR SECTIONS AND SPLICED AND INSTALLED ON A/C BS 947 PLUS 10 INCHES TO BS 1016, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)