CLT - DURING Q-6 AND HFEC CHECK VISUAL INSPECTION, FOUND TWO 2 INCH LONG CRACKS IN THE SKIN AT STATION 727D PLUS 6 BL 2L AND BL 2R. INSTALLED DOUBLER PER REPAIR DOCUMENT SRM 53-60-01. (M)