What was found
PIT - DURING Q-1 CHECK, FOUND .5 INCH CRACK AT VERTICAL LEG OF LT VERTICAL STAB DRAG ANGLE AT STATION 1288 CANTED. INSTALLED NESTED ANGLE PER SRM 53-05 FIG 23B. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK, FOUND .5 INCH CRACK AT VERTICAL LEG OF LT VERTICAL STAB DRAG ANGLE AT STATION 1288 CANTED. INSTALLED NESTED ANGLE PER SRM 53-05 FIG 23B. (M)