What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 1 INCH AROUND NUT PLATES STATION 235 BL '0' TO RBL 15 NOSE W/W CEILING TRANSVERSER BEAM. REMOVED AND INSTALLED NEW PREFAB TRANSVERSER BEAM, FABRICATED AND INSTALLED ZEE STRAPS. REPAIRED PER SRM 51-10-1 DRAWING 69-37989. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)