What was found
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 4 INCH BY 4 INCH STATION 908, STRINGER 21L. CUT OUT DAMAGE AND INSTALLED STRINGER, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION 4 INCH BY 4 INCH STATION 908, STRINGER 21L. CUT OUT DAMAGE AND INSTALLED STRINGER, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)