What was found
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 4 INCH CRACK ON FLOORBEAM 344.17 UPPER 'T' CAP LBL 7 TO LBL 35. CORROSION NR C53-170-02. REPAIRED 'T' CAP TO FLOORBEAM PER TYPICAL REPAIR 53-10-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND 4 INCH CRACK ON FLOORBEAM 344.17 UPPER 'T' CAP LBL 7 TO LBL 35. CORROSION NR C53-170-02. REPAIRED 'T' CAP TO FLOORBEAM PER TYPICAL REPAIR 53-10-03. (M)