What was found
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 3 FEET TO 6 FEET CORRODED AREA STR 25R BETWEEN STA 947.6 AND STA 967. INSTALLED STRINGER SPLICE AND REPAIRED PER SRM 53-10-3. CORROSION TASK NR: C53-202-01. CORROSION LEVEL; 2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 3 FEET TO 6 FEET CORRODED AREA STR 25R BETWEEN STA 947.6 AND STA 967. INSTALLED STRINGER SPLICE AND REPAIRED PER SRM 53-10-3. CORROSION TASK NR: C53-202-01. CORROSION LEVEL; 2. (X)