What was found
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 3 INCH CRACK BS 500 FRAME BETWEEN STR 28L AND STR 28R. INSTALLED DOUBLER AND FILLER, REPAIRED PER SRM 51-40-3. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-5' CHECK VISUAL INSPECTION, FOUND 3 INCH CRACK BS 500 FRAME BETWEEN STR 28L AND STR 28R. INSTALLED DOUBLER AND FILLER, REPAIRED PER SRM 51-40-3. (X)