What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CRACK 1 INCH LONG STATION 706 TO 714 BL '0' LONGITUDINAL FLOORBEAM. INSTALLED DOUBLER REPAIRED PER SB 737-57-1210 AND EA 43855. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CRACK 1 INCH LONG STATION 706 TO 714 BL '0' LONGITUDINAL FLOORBEAM. INSTALLED DOUBLER REPAIRED PER SB 737-57-1210 AND EA 43855. (M)