What was found
CLT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION ON UPPER FLANGE OF FLOORBEAM STATION 312 AT BL 0 UPPER CHORD. CORROSION TASK CARD NR C53-107-01. INSTALLED DOUBLER REPAIR PLATES ON UPPER FLANGE (FWD) PER REPAIR DOCUMENT SRM 51-70-12. (M)