What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SURFACE CORROSION ON STRINGER STATION 420-440 STRINGER 7R, 1 FT BY 3 INCH. REMOVED AND REPLACED STRINGER 7R FROM STRINGER 420-440. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SURFACE CORROSION ON STRINGER STATION 420-440 STRINGER 7R, 1 FT BY 3 INCH. REMOVED AND REPLACED STRINGER 7R FROM STRINGER 420-440. (M)