As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SEVERAL CORRODED AREAS .25 INCH BY .25 INCH EACH STRINGER 3R BS 440 TO BS 460. SPLICED IN NEW SECTION OF STRINGER, REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)