What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION ON STRINGER 7R AND STRINGER 5R BS 460-480, .75 INCH BY 2 INCH. INSTALLED STRINGER REPAIRS AND REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION ON STRINGER 7R AND STRINGER 5R BS 460-480, .75 INCH BY 2 INCH. INSTALLED STRINGER REPAIRS AND REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)