INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND SURFACE CORROSION ON STRINGER 8R STATION 365, 1 INCH BY 3 INCH. SPLICES IN NEW SECTION OF STRINGER, REPAIRED PER SRM 53-10-2 FIG 3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)