What was found
PHL - DURING RON, FOUND 2 CRACKS, IN EACH LONG RIGHT SIDE FUSELAGE SKIN BETWEEN STATION 797 AND 767 BETWEEN STRINGER 18RT AND 19RT. INSTALLED TEMPORARY EXTERNAL DOUBLER PER SRM 53-30-3 PAGE 2E, FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHL - DURING RON, FOUND 2 CRACKS, IN EACH LONG RIGHT SIDE FUSELAGE SKIN BETWEEN STATION 797 AND 767 BETWEEN STRINGER 18RT AND 19RT. INSTALLED TEMPORARY EXTERNAL DOUBLER PER SRM 53-30-3 PAGE 2E, FIG 1. (M)