As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM AT CLIP NUT HOLES STATION 1661 FROM BL 0 TO RBBL 55. CORROSION CARD NR C53-251-03. INSTALLED REPAIR 'T' CAP AND STRAPS. PARTIAL 'T' CAP REPLACED FROM LBL 25 TO LBL 64 ALSO INSTALLED REPLACEMENT CHORD/REPAIR ANGLES PER SRM 53-00-51 FIG 201. (M)