What was found
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION BS 1500 LBL 04-LBL 19 ON FRAME ASSY. INSTALLED NEW FRAME PER SRM 51-10-00 BAC DWG 146N1045. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING C-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION BS 1500 LBL 04-LBL 19 ON FRAME ASSY. INSTALLED NEW FRAME PER SRM 51-10-00 BAC DWG 146N1045. (M)