What was found
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1.3750 INCH AREA OF CORROSION ON FLOORBEAM STA 106 LBL 18. INSTALLED T-CAP PER TR 53-10-05C. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1.3750 INCH AREA OF CORROSION ON FLOORBEAM STA 106 LBL 18. INSTALLED T-CAP PER TR 53-10-05C. (X)